Microwave Digestion System
YMW-HP infrared temperature measurement series Microwave Digestion System as an efficient sample pretreatment equipment, which can provide fast ,safety and clean digestion treatment for users. Also it can expedite the chemical reaction speed and depth of samples under the condition of high temperature and high pressure. So the digestion system will not damage the elements such as highly volatile silver, mercury etc. Widely applied in the chemistry industry, food analysis, environmental monitoring, disease control center, quality supervision and commodity inspection etc.
APPLICATION AREA
YMW-HP infrared series Microwave Digestion System is mainly used for chemical digestion of samples at certain temperature and pressure,such as: sample pretreatment for AAS, ICP and other spectrometers. Digestion reagents can be Nitric Acid (65%), Hydrochloric Acid, Hydrofluoric Acid, Sulfuric Acid and mixed Acid. The maximum sample weight of organic sample is approximately 0.3g, (depend on the carbon content of the organic sample). The digestion temperature can reach about 200°C. Digestion or drying temperature morer than 280 ℃may cause damage to the Teflon (TEFLON-TFM) digestion tank (this temperature critical point sometimes be reached during overreaction). The maximum temperature of this device is locked below 200 ℃.
TECHNICAL PARAMETERS
Model No.
YMW-HP100
YMW-HP200
Power Supply
220-240 VAC 50/60Hz 16A
Microwave Source
2450MHz, high energy microwave field emission, dual magnetron emission
Power
2300w
2600W
Max Output Power
Continuous automatic microwave control
Control Way
7-inch capacity color touch screen, Chinese/English system
Microwave Cavity
67L large volume 304 stainless steel cavity, multi-layer corrosion-resistant PFA Teflon coating
Safety Explosion-proof Door Design
Double-layer metal structure safety door, electronic & mechanical dual control
Abnormal State Check
Intelligent judgment of abnormal state inside the cavity to prevent accidents, door state monitoring, the microwave cannot be started unless the door is closed
Turntable Design
Coaxial one-way rotation, suitable for turntables with various tank position
Pressure Measurement System
Piezoelectric crystal pressure transmission, measuring range: 0-20MPa (2500psi), accuracy ±0.01 Mpa
Temperature Measurement Method
Infrared temperature measurement: temperature range: 0-400°C, accuracy ±1°C, control accuracy ±0.1°C
Furnace Exhaust System
High-power, corrosion-resistant axial flow fan, high-efficiency air cooling, only 20 minutes from 200°C to 70°C.
Working Environment Temperature/Humidity
Working temperature: 0-40 degrees, working humidity: 15-85%RH
Overall External Dimension
645X560X650mm
Net weight
55kgs
65kgs
MAIN PARAMETERS OF DIGESTION TANK
Model
HP-100
HP-200
Position
24/40position
16position
Inner Tank Material
TFM
Dissolve The Rotor Frame Structure
Digestion tank rack type, independent installation, sealed
Reaction Tank Volume
55ml
110ml
Work Pressure
6.5MPa(1000psi)
Maximum Temperature
300°C
HF resistant
Yes
Explosion-proof Reaction Tank
Material deformation and pressure relief, automatic recovery,no consumable
Material deformation and pressure relief, automatic recovery,
no consumable