Amerex HG Series Portable Top Loading Autoclaves

Amerex HG Series Portable Top Loading Autoclaves

Amerex HG Series Portable Top Loading Autoclaves

Features:

  • Automatic lid opening button replaces a foot-pedal
  • Automatic lid closing button closes and locks lid conveniently and safely
  • New body design with larger diameter and shorter height
  • Safety interlock senses pressure and temperature and prevents lid from opening when the chamber is pressurized, temperature is too high, and also during a cycle
  • Programmable auto-start for running a cycle up to 99 hours later
  • Efficient 15 liter steam condenser eliminates steam exhaust into the lab
  • Over-flow lamp indicates that the drain bottle is full and ready to be emptied
  • Built-in fan for faster post-sterilization cooling and shorter completion time
  • Selectable rate of steam venting after sterilization
  • Programmable time for air removal before sterilization
  • Large control and display panel improves functionality and shows the progress of the sterilization cycle
  • Not intended for medical use

Specifications:

MODEL

HG-50

HG-80

Overall (W x D x H)

19.7" x 27.2" x 35.0"

(45.5 cm x 6.91 cm x 89.0 cm)

19.7" x 27.2" x 40.6"

(45.5 cm x 69.1 cm x 103.0 cm)

Chamber

(Diameter x Height)

50 liters

14.3" x 18.2" (36.4 cm x 47.0 cm)

76 liters

14.3" x 28.7" (36.4 cm x 73.0 cm)

Temperature Range

105°C to 135°C

Sterilization Timer

1 to 300 minutes

Agar Warming Range

After sterilization, agar can be maintained from 45°C to 60°C (programmable) for up to 24 hours to prevent coagulation

Delayed Auto-Start

Program autoclave to start 1 to 99 hours later

Cooling Fan

Switch to turn fan on or off

Air Removal Timer

Programmable, 3 to 9 minutes after temperature has reached 97°C

Steam Venting

Selectable from: No venting and three other venting rates

Temperature for Release of Lid Interlock

Programmable, 60°C to 97°C for greater safety and flexibility

Sterilization Program Cycles

1) Liquid cycle, 2) Agar (liquid with warming) cycle, and 3) Solid cycle

Additional Cycles for Agar Dissolution

Cycle for dissolving and keeping agar warm (no sterilization)

Agar Dissolution Protocol

Initially at 60°C-100°C for 1-60 min., then at 45°C-60°C for up to 24 hrs.

Safety Features

Circuit breaker with GFCI, low-water power cut-off, over-temp power cutoff, over-pressure power cut-off, safety valve, sensor for improper lid closing

Steam Condenser

15-liter water tank

Drain Water Bottle

2 liters

Power Requirements

120V or 220V, 50/60 Hz, single phase

220V, 50/60 Hz, single phase

Power Consumption

2.0kW, optional 3.0kW for 220V only

3.9 kW

Shipping Weight

180 lb (82 kg)

255 lb (116 kg)