BioGO 24 BSL-2 Mobile Laboratory

BioGO 24 BSL-2 Mobile Laboratory

bioGO 24 BSL-2 Mobile Laboratory

Features

Interior Materials:
Walls and Ceiling - Seamless wall system
Panels come in 40 foot lengths to minimize wall seams.
Corners permanently sealed with an epoxy compound specifically designed for this purpose.
The end result is a monolithic barrier that is durable and easily cleaned.

Flooring:

Finished floor will be a high performance, homogenous, welded seam sheet polyurethane floor.

Casework:

Type 304 Stainless Steel work casework.
Purpose built, all welded construction with adjustable shelving.

Constructed for Cleanability:

Germfrees Mobile Biocontainment Laboratories are designed to be exceptionally durable. To achieve this, only the highest grade, cleanroom-compatible materials are used in the facilitys construction. The interior walls are constructed of an exclusive high performance composite that provides a seamless interior suitable for frequent wash-downs with sanitizing agents as well as gas biodecontamination. The floor is seamless vinyl, coved up the walls, and epoxy-sealed to the walls for ease-of-cleaning. All work surfaces are seamless stainless steel with casework designed for gas and vapor phase decontamination. Surfaces are coved for easy spill cleanup and sanitization. Edges are rounded and polished to avoid snagging Personal Protective Equipment (PPE). Keyless entry main door.

Standards & Codes:

Germfrees bioGO Mobile Biocontainment Laboratories meet or exceed the requirements of the CDC NIH BMBL 5th edition for BSL-2 Laboratories. Via enhancements beyond BMBL requirements, the bioGO Mobile Biocontainment Laboratory units comply with the WHO Laboratory Biosafety Manual for BSL-3 laboratories.

Project Management:
A dedicated project manager will oversee all aspects of your laboratory purchase from order through delivery. In so doing, it is possible to guarantee a seamless transition into your bioGO Mobile Biocontainment Laboratory.

MEP

Mechanical Specifications:

A heating, ventilation and air conditioning (HVAC) system is installed in the bioGO facility. The HVAC system is engineered to maintain a comfortable working temperature and humidity, and provides an inward flow of air into the BSL-2 laboratory.

Electrical Specifications:

Connections for utility power and/or auxiliary generator inputs are provided via transfer switch. Diesel electric generator packages are optionally available and can be supplied by local equipment rental companies.

Electrical requirements will vary by region. Germfree will configure the laboratory power to meet any international standard.

Shore Power Requirements:

110-230V, 50/60Hz, 3Ph, 60A. Single point connection, shore power inputs are provided.

Plumbing Specifications:

The plumbing system includes an on-board fresh water tank and an on-demand electric water pump to provide running water for the sinks. The capacity of the laboratory water tank is supplemented by a connection to a water utility tap. The fresh water tank is equipped with a low-level monitor. A gray water tank is designed to be gravity drained. The laboratory will arrive completely plumbed, ready for connection to water supply and drain lines. The gray water tank is equipped with a high-level monitor.

Stainless Steel Sink in anteroom Includes emergency eyewash 20-Gal fresh water tank Compatibility for connection to a water utility tap 2.4 kW on-demand electric water pump 25-Gal gray water tanks Gravity drained or storage for batch dumping PEX supply and CPVC drain lines Single point of connection

Controls, Communications & Recording Systems

Communication Ports (12) Data ports are provided for network instruments, computer workstations and printers. Cables are run in shielded chases to a patch panel in the Anteroom. Telephone port is provided in the Anteroom.