Pharma Technology

Pharma Technology

Rue Graham Bell 8, B-1402 Thines (Nivelles)

Dust Tight – 4 Parameters tablet tester

Dust Tight – 4 Parameters tablet tester

Dust Tight – 4 Parameters tablet tester

The DT” 4 parameters tester is a new generation of automatic tablet testing system for integrated process control (IPC). Intended for use as a stand-alone equipment with its own HMI or in combination with an upward conveying tablet deduster, the module offers premium analysis capabilities in testing tablets weight, thickness, hardness and length/diameter.

Key benefits

  • Extremely quiet testing environment with no air turbulence - Very accurate measurement
  • Complete separation between product and mechanical/electrical area to increase operator safety
  • Tablets transfer by vacuum allowing less dust contamination in the tester area
  • CFR 21 Part 11 compliant software
  • Easy cleaning, validation and calibration

At the core of the unit design is the strict separation of dust or tablet fragments from the production flow, in a continuous   manufacturing process. Tablets are sampled directly on the press and conveyed through a flexible hose to the tester via vacuum. Sample tablets are tested for each parameter against pre-programmed recipes.
Utmost care has been taken to simplify the design for cleaning procedures. This new tester design, which includes a net  separation between the product area and the mechanical/electrical parts, increases safety during maintenance operations. All the parts are accessible and easily disassembled without the use of tools, making the system extremely easy to service and maintain. Also available in C” Containment ≤OEB4 and HC” High Containment ≤OEB5 washable.

Technical Data

Weighing measurment:

 

Weighing cell

Sartorius WZA224-L

Weighing unit

1 mg/0,1 mg (adjustable)

Weighing range

10 mg - 50 g

Weighing accuracy

±1 mg in stable environment

Thickness measurment:

 

Drive

Stepper-Motor

Measurement principle

Magnetic Sensor

Measurement unit

mm or inch

Measurement range

3 - 18 mm

Measurement accuracy

± 0,05 mm

Hardness measurment:

 

Drive

Stepper-Motor

Force measurement

Load measurement cell

Measurement principle

Strain measurement strip (DMS)

Force Units

N (Kp, Sc)

Measurement range

4-400 N, extended 8-800 N

Measurement accuracy

± 2 N (with 800 N ±4 N)

Force increase

250 N/sec

Work speed pressure jaw

0,35 mm/sec

Approach and Return speed pressure jaw

8,5 - 17 mm/sec adjustable

Diameter measurment:

 

Drive

Stepper-Motor

Measurement principle

Stepper-Motor

Measurement unit

mm (inch)

Measurement range

3 - 25 mm

Measurement range Oblong

5 - 20 mm

Measurement accuracy

±0,1 mm

General information:

 

Containment level

"DT" Dust tight

Samples conveying

Dust-Tight aspiration (optionnal venturi if not sufficient vacuum at the customer location)

Requested air extraction

Between 150-200 m3/h - Between 50-2000 Pa

Dust extraction connection

Mini Flex Connect ©

Requested compressed air

min. 4 bar

Compressed air connection

QS8

Power supply & Frequency

110V/230V - 50 Hz/60 Hz

Polymer contact parts

PMMA - PX 280 FDA - POM C

Contact parts finishing

RA <0,5 µm

Frame parts

Stainless steel 304

Frame finishing

Mirror polished

Frame mounted on wheels

Yes

IQ-OQ protocol

Available

Material certificates

Available

Total height (without HEPA filter)

1176 mm

Inlet height (Double inlet)

1130 mm

Floor dimensions (WxL)

484 mm x 490 mm

Inlet chute 4-P tester

Flex Connect ©

Outlet chute 4-P tester

TC DIN 32676 DN 50

Packing

Box on 1US pallet

Net weight 4-P tester (+/- 5Kg)

75 Kg

Product Enquiry

SSL Secure Connection